Remote Control Commands
R&S
®
SMU200A
659Operating Manual 1007.9845.32 ─ 15
Parameters:
SOFTware|MARKer
SOFTware
Recording of signals is started automatically in specified intervals.
This asynchronous method is appropriate when a representative
display of the complete signal is desired, as recording starts in a
random time reference to the signal.
MARKer
The starting point for recording signals is determined by "Marker
1" in the menu of the active standard.
This synchronous method is appropriate when specific signal
segments are to be shown in greater detail. With periodic signals,
a static image is obtained by selecting a period length of "Marker
1" that is equal to the signal period.
The displayed signal segment can be shifted as needed by
entering a "Marker Delay" in the "Trigger/Marker" menu of the
active standard.
SOFTware
<Source>
*RST:
BB:GRAP:TRIG:SOUR MARK
sets the trigger source.
Example:
7.15.3.5 SOURce:BB:IMPairment Subsystem
This subsystem contains the commands for the digital I/Q impairments.
Included in this section is also the description of command
SOURce:BB:IQOutput:SOURce that determined the source for the I/Q output connec-
tors.
[:SOURce<hw>]:BB:IMPairment:IQRatio..........................................................................660
[:SOURce<hw>]:BB:IMPairment:LEAKage:I......................................................................660
[:SOURce<hw>]:BB:IMPairment:LEAKage:Q....................................................................660
[:SOURce<hw>]:BB:IMPairment:OPTimization:MODE.......................................................661
[:SOURce<hw>]:BB:IMPairment:OPTimization:STATe.......................................................661
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:ACCuracy..............................661
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:BWIDth..................................662
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:CATalog................................662
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:EDEVices..............................662
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:FILE......................................663
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:FILE:STATus.........................663
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:FREQuency:MAX...................664
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:FREQuency:MIN....................664
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:FREQuency:OFFSet...............665
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:IAFixed..................................665
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:LEVel:MAX............................665
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:LEVel:MIN.............................666
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:LEVel:OFFSet........................666
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:TYPE....................................666
SOURce Subsystem