Remote Control Commands
R&S
®
SMU200A
696Operating Manual 1007.9845.32 ─ 15
Parameters:
A|B|AB
A
The external baseband signal is introduced into path A. The
signals are summed if necessary.
B
The external baseband signal is introduced into path B. The
signals are summed if necessary.
AB
The external baseband signal is introduced into path A and path
B. The signals are summed if necessary.
A
<Route>
*RST:
BBIN:ROUT A
The external baseband signal is introduced into path A.
Example:
[:SOURce]:BBIN:SKEW <Skew>
This command determines the delay between Q and I channel. Positive values represent
a delay for Q versus I.
Parameters:
float
-1ns to +1ns
1ps
0
s
<Skew>
Range:
Increment:
*RST:
Default unit:
BBIN:SKEW -23PS
enters a delay between Q and I channel of 23 picoseconds.
Example:
[:SOURce]:BBIN:SRATe:ACTual?
This command queries the sample rate of the external digital baseband signal.
Note: The maximum value is 90 MHz with BBinR Revision 02.xx and 100 MHz with BBinR
Revision 03.00 or higher.
Return values:
float
400 Hz to 100 MHz
<Actual>
Range:
BBIN:SRAT
queries the sample rate value of the external digital baseband sig-
nal.
Example:
Query onlyUsage:
SOURce Subsystem