Remote Control Commands
R&S
®
SMU200A
691Operating Manual 1007.9845.32 ─ 15
[:SOURce]:BBIN:OLOad:HOLD:RESet.............................................................................694
[:SOURce]:BBIN:OLOad:HOLD:STATe............................................................................694
[:SOURce]:BBIN:OLOad:STATe......................................................................................694
[:SOURce]:BBIN:PGAin..................................................................................................695
[:SOURce]:BBIN:POWer:PEAK.......................................................................................695
[:SOURce]:BBIN:POWer:RMS.........................................................................................695
[:SOURce]:BBIN:ROUTe................................................................................................695
[:SOURce]:BBIN:SKEW..................................................................................................696
[:SOURce]:BBIN:SRATe:ACTual.....................................................................................696
[:SOURce<hw>]:BBIN:SRATe:FIFO[:STATus]..................................................................697
[:SOURce<hw>]:BBIN:SRATe:SOURce...........................................................................697
[:SOURce]:BBIN:STATe.................................................................................................697
[:SOURce]:BBIN:ALEVel:EXECute
This command starts measuring the input signal. The measurement estimates the crest
factor and the peak power.
BBIN:ALEV:EXEC
starts measuring the input signal.
Example:
EventUsage:
[:SOURce<hw>]:BBIN:CDEVice?
Digital Input only.
Indicates the ID of an externally connected R&S Instrument or R&S Device.
Return values:
string<CDevice>
BBIN:CDEV
queries the connected device ID.
Example:
Query onlyUsage:
[:SOURce]:BBIN:CFACtor <Cfactor>
This command enters the crest factor of the external baseband signal.
Parameters:
float
0 to 100
0.01dB
0dB
dB
<Cfactor>
Range:
Increment:
*RST:
Default unit:
BBIN:CFAC 10
enters a crest factor of 10 dB for the external baseband signal.
Example: