Remote Control Commands
R&S
®
SMU200A
652Operating Manual 1007.9845.32 ─ 15
[:SOURce<hw>]:BB:DM:DLISt:SELect <Select>
The command selects the data list in the default directory. The default directory is set
using command MMEM:CDIRectory. A path can also be specified, in which case the
files in the specified directory are selected. If a data list with the specified name does not
yet exist, it is created. The file extension may be omitted. Only files with the file extension
*.dm_iqd will be selected or created.
The modulation data in this data list is used when the data source is selected using the
command SOURce:BB:DM:SOURce DLISt.
Setting parameters:
<list name><Select>
BB:DM:DLIS:SEL 'd_list2'
selects data list d_list2.
Example:
Setting onlyUsage:
[:SOURce<hw>]:BB:DM:FLISt:DELete <Delete>
Deletes the secified user filter file. The default directory is set using command
MMEM:CDIRectory. A path can also be specified, in which case the files in the specified
directory are read. The file extension may be omitted. Only files with the file extension
*.vaf*.vaf will be deleted.
Setting parameters:
string<Delete>
BB:DM:FILT:TYPE USER
selects the User filter type.
MMEM:CDIR 'D:/user/Filter_List'
sets the default directory for the user-defined filters.
BB:DM:FLIS:DEL user_filter3
deletes the user-defined filter.
Example:
Setting onlyUsage:
[:SOURce<hw>]:BB:DM:FLISt:POINts?
Queries the user filter list length.
Return values:
float<Points>
BB:DM:FILT:TYPE USER
selects the User filter type.
BB:DM:FLIS:POIN?
queries the list length.
Example:
Query onlyUsage:
SOURce Subsystem