617Operating Manual 1007.9845.32 ─ 15
MMEM:CDIR 'D:/user/waveform'
sets the default directory to D:/user/waveform.
BB:ARB:WSEG:CONF:SEL 'new'
creates the configuration file new.inf_mswv in the default direc-
tory.
BB:ARB:WSEG:CONF:SEGM:APP 'arb1'
appends waveform arb1.wv to configuration file new. Waveform
arb1 will be the first segment of a multi segment waveform cre-
ated with configuration file new.
Example:
Setting onlyUsage:
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:SEGMent:CATalog?
This command queries the segments of the currently selected configuration file.
Return values:
string<Catalog>
MMEM:CDIR 'D:/user/waveform'
sets the default directory to D:/user/waveform.
BB:ARB:WSEG:CONF:SEL 'multi_sin'
selects the configuration file multi_sin.inf_mswv .
BB:ARB:WSEG:CONF:SEGM:CAT?
queries the segments of the selected configuration file.
Response: arb4, arb2
The configuration file includes the segments arb4.wv and
arb2.wv.
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:ARB:WSEGment:CREate <Create>
This command creates a multi segment waveform using the current settings of the speci-
fied configuration file. The multi segment waveform is saved into the file defined in the
configuration file. The file extension is *.wv.
Setting parameters: