Remote Control Commands
R&S
®
SMU200A
784Operating Manual 1007.9845.32 ─ 15
Parameters:
float
0.01 to 165 dB
0.01dB
1
dB
<Logarithmic>
Range:
Increment:
*RST:
Default unit:
SWE:POW:STEP 10dB
sets the step width for logarithmic sweep spacing to 10 dB of the
previous level in each instance (for a level sweep at RF output).
Example:
[:SOURce<hw>]:SWEep:RESet[:ALL]
The command resets all active sweeps to the starting point.
SWE:RES
resets all active sweeps to the starting point.
Example:
7.16 STATus Subsystem
This system contains the commands for the status reporting system. *RST
on page 492 has no effect on the status registers.
Queries return the current value of the respective register, which permits a check of the
device status. A decimal value between 0 and 32767 (=215-1) is returned.
The configuration commands set the respective register thus determining which status
changes of the R&S SMU causes the status registers to be changed. A decimal value
between 0 and 32767 (= 2^15-1) is set.
STATus:OPERation:CONDition.......................................................................................785
STATus:OPERation:ENABle...........................................................................................785
STATus:OPERation[:EVENt]...........................................................................................785
STATus:OPERation:PTRansition.....................................................................................785
STATus:OPERation:NTRansition.....................................................................................786
STATus:PRESet............................................................................................................786
STATus:QUEStionable:CONDition...................................................................................786
STATus:QUEStionable:ENABle.......................................................................................787
STATus:QUEStionable:NTRansition................................................................................787
STATus:QUEStionable:PTRansition.................................................................................787
STATus:QUEStionable[:EVENt].......................................................................................788
STATus:QUEue[:NEXT]..................................................................................................788