[:SOURce<hw>]:BB:DM:CLOCk:SOURce <Source>
The command selects the source for the digital modulation clock.
For two-path instruments, selecting COUPLed and EXTernal is only possible for path A,
since the external clock source is permanently allocated to path A; clock source AINT is
only allowed for path B.
Parameters:
INTernal|EXTernal | COUPled|AINTernal
INTernal
The internal clock reference is used.
EXTernal
The external clock reference is supplied to the CLOCK connector.
COUPled
The clock reference (internal or external) is selected automatically
according to the selected data source, i.d. if the data source
changes (BB:DM:DATA:SOUR) the clock source is automatically
changed correspondingly as well.
INTernal
<Source>
*RST:
BB:DM:CLOC:SOUR INT
selects the internal clock reference.
Example:
Trigger Settings
The numeric suffix to OUTPut distinguishes between the available markers.
[:SOURce<hw>]:BB:DM:TRIGger:ARM:EXECute..............................................................626
[:SOURce<hw>]:BB:DM:TRIGger:EXECute......................................................................627
[:SOURce<hw>]:BB:DM:TRIGger:EXTernal:SYNChronize:OUTPut.....................................627
[:SOURce<hw>]:BB:DM:TRIGger:OBASeband:DELay.......................................................628
[:SOURce<hw>]:BB:DM:TRIGger:OBASeband:INHibit.......................................................628
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut:DELay:FIXed....................................................629
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay......................................................629
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay:MINimum.......................................630
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay:MAXimum......................................630
[:SOURce<hw>]:BB:DM:TRIGger:RMODe........................................................................630
[:SOURce<hw>]:BB:DM:TRIGger:SLENgth.......................................................................630
[:SOURce<hw>]:BB:DM:TRIGger:SOURce.......................................................................631
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal<ch>]:DELay..................................................631
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal<ch>]:INHibit..................................................632
[:SOURce<hw>]:BB:DM[:TRIGger]:SEQuence..................................................................632
[:
SOURce<hw>]:BB:DM:TRIGger:ARM:EXECute
The command stops signal generation for trigger modes Armed_Auto and Armed_Ret-
rigger. A subsequent internal or external trigger event restart signal generation.
SOURce Subsystem