Remote Control Commands
R&S
®
SMU200A
636Operating Manual 1007.9845.32 ─ 15
BB:DM:TRIG:OUTP2:PULS:DIV 2
sets the divider to 2 for the marker signal on output MARKER 2.
BB:DM:TRIG:OUTP2:FREQ?
queries the resulting pulse frequency of the marker signal.
Response: 66 000
the resulting pulse frequency is 66 kHz.
Example:
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PULSe:FREQuency?
The command queries the pulse frequency of the pulsed marker signal in the setting
SOURce:BB:DM:TRIGger:OUTPut:MODE PULSe. The pulse frequency is derived by
dividing the symbol rate by the divider.
Return values:
float<Frequency>
BB:DM:TRIG:OUTP2:PULS:DIV 2
sets the divider marker signal on output MARKER 2 to the value
2.
BB:DM:TRIG:OUTP2:MODE PULS
enables the pulsed marker signal.
BB:DM:TRIG:OUTP2:PULS:FREQ?
queries the pulse frequency of the marker signal.
Response: 33 000
the resulting pulse frequency is
Example:
Query onlyUsage:
Filter Settings
[:SOURce<hw>]:BB:DM:FILTer:OSAMpling......................................................................636
[:SOURce<hw>]:BB:DM:FILTer:OSAMpling:AUTO............................................................637
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine.........................................................637
[:SOURce<hw>]:BB:DM:FILTer:PARameter:GAUSs..........................................................637
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASs...........................................................637
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASSEVM...................................................637
[:SOURce<hw>]:BB:DM:FILTer:PARameter:PGAuss.........................................................637
[:SOURce<hw>]:BB:DM:FILTer:PARameter:RCOSine.......................................................637
[:SOURce<hw>]:BB:DM:FILTer:PARameter:SPHase.........................................................637
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25........................................................637
[:SOURce<hw>]:BB:DM:FILTer:TYPE..............................................................................638
[:
SOURce<hw>]:BB:DM:FILTer:OSAMpling <Osampling>
The command sets the upsampling factor.
Parameters:
float
1 to 32
32
<Osampling>
Range:
*RST:
SOURce Subsystem