[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:ONTime <Ontime>
The command sets the number of symbols in a period (ON time + OFF time) during which
the marker signal in setting SOURce:BB:DM:TRIGger:OUTPut:MODE RATio on the
marker outputs is ON.
Parameters:
float
1 to 2^20 -1 symbol
1
1
symbol
<Ontime>
Range: 
Increment: 
*RST: 
Default unit: 
BB:DM:TRIG:OUTP2:ONT 20
sets an ON time of 20 symbols for marker 2
Example:
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PATTern <Pattern>
The command defines the bit pattern used to generate the marker signal in the setting
SOURce:BB:DM:TRIGger:OUTPut:MODE PATTern. 0 is marker off, 1 is marker on.
Parameters:
integer
#B0,1  to #B111...1,32
#B,1
<Pattern>
Range: 
*RST: 
BB:DM:TRIG:OUTP2:PATT #B000000011111111,15
sets a bit pattern.
BB:DM:TRIG:OUTP2:MODE PATT
activates the marker signal according to a bit pattern on output
MARKER 2.
Example:
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PULSe:DIVider <Divider>
The command sets the divider for Pulse marker mode
(SOUR:BB:DM:TRIGr:OUTP:MODE PULSe). The resulting pulse frequency is derived
by dividing the symbol rate by the divider.
Parameters:
float
2 to 2^10
1
2
<Divider>
Range: 
Increment: 
*RST: 