Remote Control Commands
R&S
®
SMU200A
502Operating Manual 1007.9845.32 ─ 15
{SAMPLES: Samples}
(recommended for waveforms)
The tag contains the number of I/Q samples in the waveform in ASCII format.
On multi segment waveforms, this tag contains the total I/Q samples of all segments.
{SAMPLES: 4333}
BB:ARB:WAV:TAG? 'SAMPLES'
queries the content of the SAMPLES tag of the selected waveform
file.
Response: '4333'
the waveform contains 4333 I/Q samples.
Example:
Setting onlyUsage:
{[TRACE] LIST [#]: Pos0:Val0;Pos1:Val1;...Posx:Valx;...PosN-1:ValN-1}
(mandatory for control lists / optional for waveforms)
The tag contains the data for the marker and control signals in the control list or the marker
signals of ARB waveforms. To select which of these signals is defined, [TRACE] and the
associated number are used. For ARB waveforms it is only meaningful to define marker
signals (on ARB multi segment waveforms these tags will be ignored).
Setting parameters:
Specifies the name of the marker or control signal.
You may choose from the following names:
MARKER; BURST; LEVATT; CW MODE; HOP, MAP
Specifies the number in the case of control signals and marker
signals with the same name. There is a choice between 4 markers
and 3 LEVATT signals. Lines LEVATT 1 and 2 are needed for
internal purposes and should not be used.
Specifies in ASCII format the number of the position in the
sequence, with effect from which the binary state of the marker or
of the control signal changes from 0 to 1 or from 1 to 0.
Specifies the binary state of the marker or of the control signal {0;
1} from Pos
x
to Pos
x+1
exclusive in ASCII format.
[TRACE]
[#]
Pos
Val
R&S Signal Generator Waveform and List Format