EasyManua.ls Logo

Rohde & Schwarz SMU200A - [:Source<Hw>]:Bb:arb:wsegment:cload; [:Source<Hw>]:Bb:arb:wsegment

Rohde & Schwarz SMU200A
888 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMU200A
615Operating Manual 1007.9845.32 ─ 15
Section chapter 7.3, "R&S Signal Generator Waveform and List Format", on page 496
describes the ARB waveform format and how it is used to transmit waveforms via the IEC
bus.
[:SOURce<hw>]:BB:ARB:WSEGment..............................................................................615
[:SOURce<hw>]:BB:ARB:WSEGment:CLOad...................................................................615
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:OFILe...................................................616
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:SEGMent:APPend.................................616
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:SEGMent:CATalog................................617
[:SOURce<hw>]:BB:ARB:WSEGment:CREate..................................................................617
[:SOURce<hw>]:BB:ARB:WSEGment:NAME....................................................................618
[:SOURce<hw>]:BB:ARB:WSEGment:NEXT.....................................................................618
[:SOURce<hw>]:BB:ARB:WSEGment:NEXT:EXECute......................................................619
[:SOURce<hw>]:BB:ARB:WSEGment:NEXT:SOURce.......................................................619
[:SOURce<hw>]:BB:ARB:WSEGment:SEQuence:APPend.................................................619
[:SOURce<hw>]:BB:ARB:WSEGment:SEQuence:SELect..................................................620
[:SOURce<hw>]:BB:ARB:WSEGment?
This command queries the currently output segment of the multi segment waveform.
Return values:
float<Wsegment>
BB:ARB:WSEG?
queries the currently output segment.
Response 2
segment 2 is currently output.
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:ARB:WSEGment:CLOad <Cload>
This command creates a multi segment waveform using the current entries of the speci-
fied configuration file.
This multi segment waveform is saved with the file name specified in the configuration
file . The file extension is *.wv. Digital standard "ARB" is activated, the new multi segment
waveform is loaded and the first segment is output in accordance to the trigger settings.
Setting parameters:
string<Cload>
SOURce Subsystem

Table of Contents

Other manuals for Rohde & Schwarz SMU200A

Related product manuals