Remote Control Commands
R&S
®
SMU200A
726Operating Manual 1007.9845.32 ─ 15
IQ:IMP OFF
deactivates I/Q impairment.
Example:
[:SOURce<hw>]:IQ:SOURce <Source>
This command selects the input signal for the I/Q modulator.
In case of two-path instruments, this selection is only available for Path A (SOURce[1]).
The input signal for the I/Q modulator of Path B is always the internal baseband signal
(BASeband).
Selecting ANALog (Wideband I/Q In) switches off:
●
SOURce:AM:STATe OFF
●
SOURce:BBAM:STATe OFF
●
SOURce:BB:DM:STATe OFF
●
SOURce:BB:<Dig. Standard>:STATe OFF
●
SOURce:BBIN:STATe OFF
Parameters:
BASeband|ANALog
BASeband
<Source>
*RST:
IQ:SOUR ANAL
selects an external analog signal as the input signal. The signal
must be applied at the inputs I and Q.
Example:
[:SOURce<hw>]:IQ:STATe <State>
This command activates and deactivates I/Q modulation.
Parameters:
0|1|OFF|ON
OFF
<State>
*RST:
IQ:STAT ON
activates I/Q modulation.
Example:
[:SOURce<hw>]:IQ:SWAP[:STATe] <State>
When set to ON, this command swaps the I and Q channel.
Parameters:
0|1|OFF|ON
OFF
<State>
*RST:
IQ:SWAP ON
swaps the I and Q channel.
Example:
SOURce Subsystem