Remote Control Commands
R&S
®
SMU200A
651Operating Manual 1007.9845.32 ─ 15
Setting parameters:
0 | 1 {,0 | 1 }.| block data<Append>
BB:DM:DLIS:SEL ' d_list2'
selects data list d_list2.
FORM ASC
selects ASCII data transmission format.
BB:DM:DLIS:DATA:APP 1,1,1,0,0,0,1,1,0,1...
adds the specified numeric data to the existing data in data list
d_list2.
Example:
Setting onlyUsage:
[:SOURce<hw>]:BB:DM:DLISt:DELete <Delete>
The command deletes the specified data list. from the default directory. The default
directory is set using command MMEM:CDIRectory. A path can also be specified, in
which case the files in the specified directory are deleted. The file extension may be
omitted. Only files with the file extension *.dm_iqd will be deleted.
The numeric suffix on SOURce<[1]|2> is ignored in this command.
Setting parameters:
<list name><Delete>
BB:DM:DLIS:DEL ' d_list2'
deletes data list d_list2.
Example:
Setting onlyUsage:
[:SOURce<hw>]:BB:DM:DLISt:POINts <Points>
The command defines the number of bits in the selected data list to be utilized. When a
list is being filled with block data, this data is only ever sent in multiples of 8 bits. However
the exact number of bits to be exploited can be set to a different figure. The superfluous
bits in the list are then ignored.
Parameters:
float<Points>
BB:DM:DLIS:POIN 234
defines the number of bits in the data list to be utilized as 234 bits.
If the list was filled with block data, at least the last 6 bits will be
ignored.
Example: