Remote Control Commands
R&S
®
SMU200A
581Operating Manual 1007.9845.32 ─ 15
7.15.3.2 SOURce:BB:ARB Subsystem
The ARB subsystem contains the commands for setting the ARB Generator. Settings for
clock and trigger interfaces and for external outputs are entered in the SOURce:INPut
and SOURce:OUTput subsystems.
Section chapter 7.3, "R&S Signal Generator Waveform and List Format", on page 496
describes the ARB waveform format and how it is used to transmit waveforms via the IEC
bus.
● Common Settings..................................................................................................581
● Clock Settings.......................................................................................................582
● Trigger Settings.....................................................................................................583
● Marker Settings.....................................................................................................592
● Test Signals Settings............................................................................................594
● SOURce:BB:ARB:MCAR Subsystem...................................................................597
● SOURce:BB:ARB:WAV Subsystem......................................................................610
● SOURce:BB:ARB:WSEG Subsystem...................................................................614
Common Settings
[:SOURce<hw>]:BB:ARB:PRESet....................................................................................581
[:SOURce<hw>]:BB:ARB:STATe.....................................................................................581
[:SOURce<hw>]:BB:ARB:PRESet
The command sets all ARB generator parameters to their default values.
BB:ARB:PRES
resets the ARB generator to default values.
Example:
EventUsage:
[:SOURce<hw>]:BB:ARB:STATe <State>
The command enables the ARB generator. Any other standards or digital modulation that
may be in the ON state are automatically turned OFF.
In case of two-path instruments, this affects the same path.
ARB:STAT ON is only possible after the selection of a waveform. The selected waveform
is output straight away (ARB:SEQ AUTO|RETRigger) or after the first trigger event
(ARB:SEQ AAUT|ARET), depending on the trigger setting.
Parameters:
0|1|OFF|ON
OFF
<State>
*RST:
SOURce Subsystem