EasyManua.ls Logo

Rohde & Schwarz SMU200A - Page 669

Rohde & Schwarz SMU200A
888 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMU200A
649Operating Manual 1007.9845.32 ─ 15
Setting parameters:
<list name><Delete>
BB:DM:CLIS:DEL 'c_list3'
deletes control list c_list3.
Example:
Setting onlyUsage:
[:SOURce<hw>]:BB:DM:CLISt:POINts?
The command queries the number of lines (2 bytes) in the currently selected list.
Return values:
float<Points>
BB:DM:CLIS:SEL "c_list1"
selects control list c_list1.
BB:DM:CLIS:POIN?
queries the number of lines in the control list.
Response: 20
the control list consists of 20 lines.
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:DM:CLISt:SELect <Select>
The command selects the control list in the default directory. The default directory is set
using command MMEM:CDIRectory. A path can also be specified, in which case the
files in the specified directory are selected. If a control list with the specified name does
not yet exist, it is created. The file extension may be omitted. Only files with the file
extension *.dm_iqc will be selected or created.
Setting parameters:
<list name><Select>
BB:DM:CLIS:SEL 'c_list1'
selects control list c_list1.
Example:
Setting onlyUsage:
SOURce Subsystem