Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual 2-245
FIP 1. 252
041-340 IOT NVRAM Error
Cause:
The operation error of NVM (read/write check error etc.) is detected.
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace (REP 5.6 MCU PWB).
FIP 1. 253
041-347 IOT I/F Failure
Cause:
MCU Internal Error (I/F part).
Solution:
1. Turn the power Off and On to check that the error recurs
2. Update to the latest F/W.
3. If the problem cannot be solved, replace the following parts in sequence.
•(REP 5.6 MCU PWB)
•(REP 5.1 ESS PWB)