Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual2-318
FIP 2.05
MSI No Paper Sensor
Cause:
Parts to be considered:
• MSI NO PAPER ACTUATOR (PL 2.6 MSI)
• MSI NO PAPER SENSOR (PL 5.3 Electrical (MCU PWB / HVPS))
• HVPS HARNESS ASSEMBLY (PL 5.4 Electrical Connections)
•MCU PWB (PL 5.3 Electrical (MCU PWB / HVPS))
Solution:
Step Check and Action Yes No
1
Are there any foreign substances in the MSI
NO PAPER SENSOR HVPS DETECTOR?
Remove the for-
eign substances
Go to Step 2.
2
Is the MSI NO PAPER ACTUATOR damaged?
Replace the MSI
NO PAPER ACTU-
ATOR
Go to Step 3.
3
Check the connection between the HVPS and
the MCU PWB.
• Is the HVPS HARNESS ASSEMBLY(P/J261 -
P/J26) connected securely?
Go to Step 4.
Securely connect
the HVPS HAR-
NESS ASSEMBLY
4
• Replace the HVPS HARNESS ASSEMBLY.
• Does an error occur?
Go to Step 5.
Troubleshooting
complete.
5
•Replace (REP 5.7 HVPS (3610)) (REP 5.8
HVPS (3615))
• Does an error occur?
Replace
(REP 5.6 MCU
PWB)
Troubleshooting