Service Parts Disassembly
Phaser 3610, WorkCentre 3615 Service Manual4-32
REP 2.2 Transport Assembly
PL 2.4 Duplex Chute
Removal
WARNING: Allow the Fusing Assembly to cool before servicing the product.
1. Remove all Trays.
2. Remove the Drum Cartridge.
3. Remove (REP 1.7 Left Side Cover (3610)) (REP 1.17 Lower Left Side Cover (3615)).
4. Remove (REP 1.6 Right Side Cover (3610)) (REP 1.14 Right Inner Cover (3615)).
5. Remove (REP 5.1 ESS PWB).
6. Remove (REP 3.5 Fusing Assembly).
7. Remove (REP 4.1 Main Drive Assembly).
8. Remove (REP 5.7 HVPS (3610)) (REP 5.8 HVPS (3615)).
9. Remove the Interlock Switch Assembly. (Figure 1)
a. Remove 1 screw.
b. Release 2 tabs on the bottom of the assembly, move to the left to remove, but do not
disconnect the assembly.
Figure 1
s3610-067
b)
b)
a)