Specifications
Phaser 3610, WorkCentre 3615 Service Manual 8-15
Operating Environment
Installation Temperature / Humidity
The temperature and non-condensing relative humidity for installation is as follows:
During operating: 10 to 32°C, 10 to 85%RH (No condensation)
At standby: minus -20 to 40°C, 5 to 85%RH (No condensation)
Installation Altitude
The machine operates normally at the altitude from 0 to 10170 ft. (0 to 3100 meters) with high-
altitude settings.
Installation Horizontality
The machine operates normally when it is installed in a horizontal position and when the maximum
inclination is 1 degree or less in the front to back direction and in the left-right direction.
Storage Temperature of a Toner Cartridge
The guaranteed period of an unpacked print cartridge is as follows:
Normal conditions: 24 months under 0 to 35°C, 15 to 80% RH.
Harsh conditions: 1 month under -20 to 0°C and 35 to 40°C, 5 to 15% RH, 95% RH.
The storage altitude shall be0 to 10,170 ft. (0 to 3100 meters). This can be extended to 0 to 49,212 ft.
(0 to 15,000 meters) when shipped by air.
Note: Provided that the cargo bay is pressurized to 70.9275 Kpa or higher.