Use and maintenance
Operate the brake lever (or pedal) several times to allow the fluid to reach all points of the circuit and expel any air.
Connect the bleed tool to bleed valve (3) or (5).
Notes
Follow the manufacturer's instructions when using a commercial brake bleeding tool.
Pump with the bleeder and loosen off the bleed valve (3) or (5). Check that the reservoir level does not fall below the MIN mark.
Repeat the bleeding operation until the fluid flowing from the tube is completely free of air bubbles.
Tighten the bleed valve (3) or (5) to the specified torque (Sect. C 3).
If you do not have a brake bleeding tool available, connect a length of transparent plastic tubing to the bleed valve (3) or (5) as
described in the draining procedure.