Section
2: General operation Model DMM7510 7½ Digit Graphical Sampling Multimeter Re
ference Manual
2-156 DMM7510-901-01 Rev. B / May 2015
• Password reset: This resets the instrument password to its default value. You can reset the
password by pressing the MENU key, selecting Info/Manage (under System), and selecting
Password Reset. When you do this, the password returns to the default setting. Refer to
Instrument access (on page 3-1
).
• Digital line reset: This resets digital I/O line values to their factory defaults if you are using the
TSP command set. If you are using SCPI, the lines are reset when the system is reset.
• LAN reset: This resets the LAN settings and the instrument password to the system default
values. To do this reset, insert a straightened paper clip into hole below LAN RESET on the rear
panel. For the location of LAN RESET, refer to Rear panel overview (on page 2-6
).
• Status preset: This resets all bits in the status model. If you are using the SCPI command set,
refer to :STATus:PRESet (on page 6-132
). If you are using the TSP command set, refer to
status.preset() (on page 8-245).
• Trigger blender reset: This reset is only available if you are using the TSP command set.
Resets some of the trigger blender settings to their factory defaults. Refer to
trigger.blender[N].reset() (on page 8-256
).
• Trigger timer reset: This reset is only available if you are using the TSP command set. Resets
trigger timer settings to their default values. Refer to trigger.timer[N].reset() (on page 8-333
).
• TSP-Link line reset: This reset is only applicable if you are using TSP-Link. Resets some of the
TSP-Link trigger attributes to their defaults. Refer to tsplink.line[N].reset() (on page 8-349
).
• TSP-Net reset: This reset is only applicable if you are using TSP-NET. Disconnects all TSP-Net
sessions. Refer to tspnet.reset() (on page 8-359
).
Reset the instrument
You can reset many of the instrument settings to their default values. Default values are listed in the
command descriptions.
If you are connected to a TSP-Link system, resetting the instrument resets all TSP-Link enabled
instruments on the TSP-Link system.
Using the front panel:
1. Press MENU.
2. Under System, select Info/Manage.
3. Select System Reset.
4. The commands are reset and a confirmation message is displayed.
Using SCPI commands:
Send the command:
*RST
Using TSP commands:
Send the command:
reset()
If the instrument is connected to a TSP-Link system and you are using TSP commands, you can
reset only the local instrument by sending localnode.reset() instead of reset().

Table of Contents

Other manuals for Keithley DMM7510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley DMM7510 and is the answer not in the manual?

Keithley DMM7510 Specifications

General IconGeneral
BrandKeithley
ModelDMM7510
CategoryMultimeter
LanguageEnglish

Related product manuals