:CHANnel<n> Commands 10
Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide 213
:CHANnel<n>:PROBe:HEAD[:TYPE]
(see page 798)
Command Syntax
:CHANnel<n>:PROBe:HEAD[:TYPE] <head_param>
<head_param> ::= {SEND0 | SEND6 | SEND12 | SEND20 | DIFF0 | DIFF6
| DIFF12 | DIFF20 | NONE}
<n>::={1|2|3|4}
The :CHANnel<n>:PROBe:HEAD[:TYPE] command sets an analog channel probe
head type and dB value. You can choose from:
•SEND0 — Single-ended, 0dB.
•SEND6 — Single-ended, 6dB.
• SEND12 — Single-ended, 12dB.
• SEND20 — Single-ended, 20dB.
• DIFF0 — Differential, 0dB.
• DIFF6 — Differential, 6dB.
• DIFF12 — Differential, 12dB.
• DIFF20 — Differential, 20dB.
Query Syntax
:CHANnel<n>:PROBe:HEAD[:TYPE]?
The :CHANnel<n>:PROBe:HEAD[:TYPE]? query returns the current probe head
type setting for the selected channel.
Return Format
<head_param><NL>
<head_param> ::= {SEND0 | SEND6 | SEND12 | SEND20 | DIFF0 | DIFF6
| DIFF12 | DIFF20 | NONE}
See Also • "Introduction to :CHANnel<n> Commands" on page 203
• ":CHANnel<n>:PROBe" on page 212
• ":CHANnel<n>:PROBe:ID" on page 214
• ":CHANnel<n>:PROBe:SKEW" on page 215
• ":CHANnel<n>:PROBe:STYPe" on page 216
This command is valid only for the 113xA Series probes.