216 Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide
10 :CHANnel<n> Commands
:CHANnel<n>:PROBe:STYPe
(see page 798)
Command Syntax
:CHANnel<n>:PROBe:STYPe <signal type>
<signal type> ::= {DIFFerential | SINGle}
<n> ::= 1 to (# analog channels) in NR1 format
The :CHANnel<n>:PROBe:STYPe command sets the channel probe signal type
(STYPe) to differential or single-ended when using the 113xA Series probes and
determines how offset is applied.
When single-ended is selected, the :CHANnel<n>:OFFset command changes the
offset value of the probe amplifier. When differential is selected, the
:CHANnel<n>:OFFset command changes the offset value of the channel amplifier.
Query Syntax
:CHANnel<n>:PROBe:STYPe?
The :CHANnel<n>:PROBe:STYPe? query returns the current probe signal type
setting for the selected channel.
Return Format
<signal type><NL>
<signal type> ::= {DIFF | SING}
See Also • "Introduction to :CHANnel<n> Commands" on page 203
• ":CHANnel<n>:OFFSet" on page 211
NOTE
This command is valid only for the 113xA Series probes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision DSOX1204G and is the answer not in the manual?

Keysight Technologies InfiniiVision DSOX1204G Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision DSOX1204G
CategoryTest Equipment
LanguageEnglish

Related product manuals