686 Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide
29 :WGEN Commands
:WGEN:MODulation:FUNCtion:RAMP:SYMMetry
(see page 798)
Command Syntax
:WGEN:MODulation:FUNCtion:RAMP:SYMMetry <percent>
<percent> ::= symmetry percentage from 0% to 100% in NR1 format
The :WGEN:MODulation:FUNCtion:RAMP:SYMMetry command specifies the
amount of time per cycle that the ramp waveform is rising. The ramp modulating
waveform shape is specified with the :WGEN:MODulation:FUNCtion command.
Query Syntax
:WGEN:MODulation:FUNCtion:RAMP:SYMMetry?
The :WGEN:MODulation:FUNCtion:RAMP:SYMMetry? query returns ramp
symmetry percentage setting.
Return Format
<percent><NL>
<percent> ::= symmetry percentage from 0% to 100% in NR1 format
See Also ":WGEN:MODulation:AM:DEPTh" on page 679