254 Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide
14 :EXTernal Trigger Commands
:EXTernal:LEVel
(see page 798)
Command Syntax
:EXTernal:LEVel <level>[<suffix>]
<value> ::= external trigger level value in NR3 format.
<suffix> ::= {V | mV}
The :EXTernal:LEVel command sets the external trigger input threshold (trigger)
voltage level.
Query Syntax
:EXTernal:LEVel?
The :EXTernal:LEVel? query returns the external trigger input threshold voltage
setting.
Return Format
<value><NL>
See Also ":EXTernal:DISPlay" on page 252