420 Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide
21 :MTESt Commands
:MTESt:RMODe:FACTion:PRINt
(see page 798)
Command Syntax
:MTESt:RMODe:FACTion:PRINt <on_off>
<on_off> ::= {{1 | ON} | {0 | OFF}}
The :MTESt:RMODe:FACTion:PRINt command sets printing on mask failures on or
off.
See Chapter 18, “:HARDcopy Commands,” starting on page 311 for more
information on setting the hardcopy device and formatting options.
Query Syntax
:MTESt:RMODe:FACTion:PRINt?
The :MTESt:RMODe:FACTion:PRINt? query returns the current mask failure print
setting.
Return Format
<on_off><NL>
<on_off> ::= {1 | 0}
See Also "Introduction to :MTESt Commands" on page 401
":MTESt:RMODe:FACTion:MEASure" on page 419
":MTESt:RMODe:FACTion:SAVE" on page 421
":MTESt:RMODe:FACTion:STOP" on page 422
NOTE
Setting :MTESt:RMODe:FACTion:PRINt ON automatically sets :MTESt:RMODe:FACTion:SAVE
OFF.