EasyManua.ls Logo

Keysight Technologies InfiniiVision DSOX1204G

Keysight Technologies InfiniiVision DSOX1204G
946 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
474 Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide
24 :SBUS<n> Commands
:SBUS<n>:CAN:SIGNal:BAUDrate
(see page 798)
Command Syntax
:SBUS<n>:CAN:SIGNal:BAUDrate <baudrate>
<baudrate> ::= integer from 10000 to 4000000 in 100 b/s increments,
or 5000000
The :SBUS<n>:CAN:SIGNal:BAUDrate command sets the standard baud rate of
the CAN signal from 10 kb/s to 4 Mb/s in 100 b/s increments. If you enter a baud
rate that is not divisible by 100 b/s, the baud rate is set to the nearest baud rate
divisible by 100 b/s.
You can also set the baud rate of the CAN signal to 5 Mb/s. Fractional baud rates
between 4 Mb/s and 5 Mb/s are not allowed.
If the baud rate you select does not match the system baud rate, false triggers
may occur.
Query Syntax
:SBUS<n>:CAN:SIGNal:BAUDrate?
The :SBUS<n>:CAN:SIGNal:BAUDrate? query returns the current CAN baud rate
setting.
Return Format
<baudrate><NL>
<baudrate> ::= integer from 10000 to 4000000 in 100 b/s increments,
or 5000000
See Also "Introduction to :TRIGger Commands" on page 585
":SBUS<n>:MODE" on page 465
":SBUS<n>:CAN:TRIGger" on page 477
":SBUS<n>:CAN:SIGNal:DEFinition" on page 475
":SBUS<n>:CAN:SOURce" on page 476

Table of Contents