EasyManua.ls Logo

Keysight Technologies InfiniiVision DSOX1204G

Keysight Technologies InfiniiVision DSOX1204G
946 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
:TRIGger Commands 27
Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide 623
:TRIGger:TRANsition:QUALifier
(see page 798)
Command Syntax
:TRIGger:TRANsition:QUALifier <qualifier>
<qualifier> ::= {GREaterthan | LESSthan}
The :TRIGger:TRANsition:QUALifier command specifies whether you are looking for
rise/fall times greater than or less than a certain time value. The time value is set
using the :TRIGger:TRANsition:TIME command.
Query Syntax
:TRIGger:TRANsition:QUALifier?
The :TRIGger:TRANsition:QUALifier? query returns the current rise/fall time trigger
qualifier setting.
Return Format
<qualifier><NL>
<qualifier> ::= {GRE | LESS}
See Also "Introduction to :TRIGger Commands" on page 585
":TRIGger:TRANsition:TIME" on page 626
":TRIGger:MODE" on page 594