:MARKer Commands 19
Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide 333
:MARKer:XDELta
(see page 798)
Query Syntax
:MARKer:XDELta?
The MARKer:XDELta? query returns the value difference between the current X1
and X2 cursor positions.
Xdelta = (Value at X2 cursor) - (Value at X1 cursor)
X cursor units are set by the :MARKer:XUNits command.
Return Format
<value><NL>
<value> ::= difference value in NR3 format.
See Also • "Introduction to :MARKer Commands" on page 326
• ":MARKer:MODE" on page 328
• ":MARKer:X1Position" on page 329
• ":MARKer:X2Position" on page 331
• ":MARKer:X1Y1source" on page 330
• ":MARKer:X2Y2source" on page 332
• ":MARKer:XUNits" on page 334
NOTE
If the front-panel cursors are off, the marker position values are not defined. Make sure to set
:MARKer:MODE to MANual or WAVeform to put the cursors in the front-panel Normal mode.