Remote control commandsMXO 4 Series
787User Manual 1335.5337.02 ─ 07
Usage: Query only
Asynchronous command
SBUS<sb>:CAN:FRAMe<fr>:IDTYpe?
Returns the identifier type of the selected frame, the identifier format of data and
remote frames.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Return values:
<IdentifierType> B11 | B29
B11: standard format, 11 bit
B29: extended format, 29 bit
*RST: B11
Usage: Query only
Asynchronous command
SBUS<sb>:CAN:FRAMe<fr>:IDValue?
Returns the identifier value of the selected frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Return values:
<IdtfVal> Range: 0 to 536870911
Increment: 1
*RST: 0
Usage: Query only
Asynchronous command
SBUS<sb>:CAN:FRAMe<fr>:NDBYtes?
Returns the number of data bytes.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Return values:
<NDBytes> Range: 0 to 2048
Increment: 1
*RST: 1