Remote control commandsMXO 4 Series
809User Manual 1335.5337.02 ─ 07
<fr> index of the frame
<o> index of the byte
Return values:
<Label>
Usage: Query only
Asynchronous command
SBUS<sb>:LIN:FRAMe<fr>:CSValue?
Returns the checksum value of the specified frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Return values:
<ChecksumValue> Range: 0 to 255
Increment: 1
*RST: 0
Usage: Query only
Asynchronous command
SBUS<sb>:LIN:FRAMe<fr>:DATA?
Returns the data bytes of the specified frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Example:
BUS:LIN:FRAMe4:DATA?
<-- 4,118,39,71,123
Usage: Query only
Asynchronous command
SBUS<sb>:LIN:FRAMe<fr>:IDPValue?
Returns the value of the identifier parity bits of the selected frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Return values:
<IdtfParVal>
Range: 0 to 3
Increment: 1
*RST: 0
Protocols