Remote control commands
R&S
®
RTE
1736User Manual 1326.1032.02 ─ 20
Suffix:
<m>
.
1..4
Parameters:
<ThresholdCoupling> ON | OFF
ON
Activates coupling of the upper and lower threshold values.
OFF
Disables coupling of the upper and lower threshold values.
*RST: ON
BUS<m>:CMSB:MANChester:CPHase <ClockPhase>
Selects the phase of the custom serial bus clock signal for the "Manchester" coding
standards. For details, see "Clock Phase (Manchester)" on page 772.
Suffix:
<m>
.
1..4
Parameters:
<ClockPhase> FEDGe | SEDGe
FEDGe
Sets the sampling edge to be on the first edge.
SEDGe
Sets the sampling edge to be on the second edge.
AUTO
Lets the decoder automatically select the method ("First Edge"
or "Second Edge") for detecting the sampling edge.
*RST: SEDGe
BUS<m>:CMSB:NRZ:CLCK <SourceNRZClock>
Selects the source channel for the clock signal in the NRZ Clocked coding standard.
For triggering on the serial bus when the NRZ clocked coding standard is selected,
analog or digital channel sources are required.
Otherwise, if no serial bus trigger has been selected, permitted source selections
include the mathematical channels and the reference channels.
Suffix:
<m>
.
1..4
Parameters:
<SourceNRZClock> NONE | C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 |
M5 | M6 | M7 | M8 | R1 | R2 | R3 | R4 | D0 | D1 | D2 | D3 | D4 |
D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15
*RST: C2W1