EasyManua.ls Logo

Rohde & Schwarz RTE Series - LIN Label List; Triggering on LIN Signals

Rohde & Schwarz RTE Series
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol analysis
R&S
®
RTE
608User Manual 1326.1032.02 ─ 20
Remote command:
TRIGger<m>:LIN:CHKSerror on page 1536
TRIGger<m>:LIN:ERRPattern on page 1537
TRIGger<m>:LIN:CRCDatalen on page 1537
TRIGger<m>:LIN:STANdard on page 1537
TRIGger<m>:LIN:IPERror on page 1536
TRIGger<m>:LIN:SYERror on page 1536
13.6.3.2 Triggering on LIN signals
Prerequisites: An LIN bus is configured, see Chapter 13.2.2.2, "Configuring I²C proto-
col", on page 525.
1. Press the [PROTOCOL] key and select the "Trigger" tab.
2. Press the "Select" button. The "Source" button is shown.
3. Tap the "Source" button and select the "Serial bus" trigger source.
4. Select the serial bus that is set to LIN.
5. Select the "Trigger type".
6. For more complex trigger types, enter the address and/or data conditions: address,
identifier, frame ID.
For details, see Chapter 13.6.3.1, "LIN trigger settings", on page 604.
13.6.4 LIN label list
Label lists are protocol-specific. Label lists for LIN are available in CSV and PTT for-
mat.
You can also apply an existing LIN description file.
A LIN label file contains two values for each identifier:
Identifier value
Symbolic name for the identifier
Example of a LIN PTT file
# ----------------------------------------------------------------------------
@FILE_VERSION = 1.0
@PROTOCOL_NAME = lin
# ----------------------------------------------------------------------------
# Labels for LIN protocol
# Column order: Identifier, Label
# ----------------------------------------------------------------------------
# Labels for standard addresses
0x3F,Temperature
1Ch,Left brake
20h,Right brake
LIN (option R&S
RTE-K3)

Table of Contents

Other manuals for Rohde & Schwarz RTE Series