1757User Manual 1326.1032.02 ─ 20
Setting parameters:
<Frame>
<Field>
<Enabler> ON | OFF
Usage: Setting only
BUS<m>:CMSB:FILTer:FRAMe<n>:ENABle <Enable>
Enables or disables the specific frame to be filtered.
Suffix:
<m>
.
1..4
<n> *
Parameters:
<Enable> ON | OFF
*RST: OFF
BUS<m>:CMSB:FILTer:FRENable <Frame>, <Enabler>
Enables or disables the specific frame to be filtered.
Suffix:
<m>
.
1..4
Setting parameters:
<Frame>
<Enabler> ON | OFF
Usage: Setting only
BUS<m>:CMSB:FILTer:IMAX <Frame>, <Field>, <Data>
Sets the end value of an index range if BUS<m>:CMSB:FILTer:IOPerator is set to
INRange or RANGe.
Suffix:
<m>
.
1..4
Setting parameters:
<Frame>
<Field>
<Data>
Usage: Setting only