Remote control commands
R&S
®
RTE
1865User Manual 1326.1032.02 ─ 20
<o> *
Selects the field number.
Return values:
<FrameByteValue>
Usage: Query only
BUS<m>:SWIRe:RESults:FRAMe<n>:FLD<o>:STARt?
Returns the start time of the field with the selected field number within the frame with
the selected frame number.
Suffix:
<m>
.
1..4
<n> *
Selects the frame number.
<o> *
Selects the field number.
Return values:
<Start> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
BUS<m>:SWIRe:RESults:FRAMe<n>:FLD<o>:STATus?
Returns the status of the field with the selected field number within the frame with the
selected frame number.
Suffix:
<m>
.
1..4
<n> *
Selects the frame number.
<o> *
Selects the field number.
Return values:
<State> OK | PAR | ESC | AMB | INComplete
PAR: parity error
ESC: escape
AMB: ambiguous
*RST: OK
Usage: Query only
Protocols