Remote control commands
R&S
®
RTE
1950User Manual 1326.1032.02 ─ 20
TURN
Turn On/Off
SWIT
Switching Loss
EFF
Power Efficiency
RIPP
Ripple
TRANS
Transient Response
SPEC
Spectrum
POWer:REPort:TEST:DIRectory <MeasType>, <DirectoryPath>
POWer:REPort:TEST:DIRectory? <MeasType>
Selects the directory, in which the reports are saved.
Setting parameters:
<DirectoryPath>
Parameters for setting and query:
<MeasType> QUAL | RUSH | HARM | MODU | DONR | SLEW | SOA | TURN |
SWIT | EFF | RIPP | TRANS | SPEC
POWer:REPort:TEST:COMMent <MeasType>, <Comment>
POWer:REPort:TEST:COMMent? <MeasType>
Sets a comment for the report.
Setting parameters:
<Comment>
Parameters for setting and query:
<MeasType> QUAL | RUSH | HARM | MODU | DONR | SLEW | SOA | TURN |
SWIT | EFF | RIPP | TRANS | SPEC
POWer:REPort:TEST:COUNt <MeasType>
Parameters:
<MeasType> QUAL | RUSH | HARM | MODU | DONR | SLEW | SOA | TURN |
SWIT | EFF | RIPP | TRANS | SPEC
Return values:
<Count>
Power analysis (option R&S RTE-K31)