Protocol analysis
R&S
®
RTE
713User Manual 1326.1032.02 ─ 20
See also: Chapter 13.1.1, "Decode - general settings", on page 514.
Forward
Defines the forward signal settings.
You can choose between a differential and single-ended signal and set the forward
source channel for the waveform. Only analog channels are available for selection.
Remote command:
BUS<m>:HBTO:FTYP on page 1674
BUS<m>:HBTO:FDIF on page 1673
BUS<m>:HBTO:FDAP on page 1673
BUS<m>:HBTO:FDAM on page 1673
Reverse
Defines the reversed signal settings. The reverse direction is optional and can be dis-
abled.
You can choose between a differential and single-ended signal and set the reverse
source channel for the waveform. Only analog channels are available for selection.
Remote command:
BUS<m>:HBTO:RTYP on page 1674
BUS<m>:HBTO:RDIF on page 1674
BUS<m>:HBTO:RDAP on page 1674
BUS<m>:HBTO:RDAM on page 1674
Attenuation
Sets the attenuation factor. It is used to de-amplify the reverse signal before subtract-
ing it from the forward signal.
Ethernet 100BASE-T1 (option R&S
RTE-57)