Protocol analysis
R&S
®
RTE
875User Manual 1326.1032.02 ─ 20
"Time Code"
Searches for a time-code control code. You can define the data pat-
tern of the time code to be searched for.
"ERRORs"
Searches for an enabled error type.
Remote command:
SEARch:TRIGger:SWIRe:TYPE on page 1870
Trigger Control Type
Searches for a specific control type character.
"ANY"
Any control type character
"FCT"
Flow Control Token character
"EOP"
Normal End of Packet character
"EEP"
Error End of Packet character
Remote command:
SEARch:TRIGger:SWIRe:CTYPe on page 1867
Data (Time Code)
Sets the specified data type for the time code to be searched for. The data type setup
consists of the condition and one or two data patterns.
"Condition"
Defines the operator to set a specific data type ("Equal" or "Not
equal") or a data type range.
"Data Min/
Data"
Defines the bit pattern of the data pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.5, "Bit pattern editor", on page 521.
"Data Max"
The second data pattern is required to specify a range with conditions
"In range" and "Out of range".
Remote command:
SEARch:TRIGger:SWIRe:TIME:CONDition on page 1869
SEARch:TRIGger:SWIRe:TIME:MAX on page 1869
SEARch:TRIGger:SWIRe:TIME:MIN on page 1870
Data(Data Pattern)
Sets the specified data type for the data pattern to be searched for. The data type
setup consists of the condition and one or two data patterns.
"Condition"
Defines the operator to set a specific data type ("Equal" or "Not
equal") or a data type range.
SpaceWire (option R&S RTE-K65)