Remote Control Commands
R&S
®
SMU200A
595Operating Manual 1007.9845.32 ─ 15
[:SOURce<hw>]:BB:ARB:TSIGnal:CIQ:CREate:NAMed <Named>
[:SOURce<hw>]:BB:ARB:TSIGnal:RECTangle:CREate:NAMed <Named>
[:SOURce<hw>]:BB:ARB:TSIGnal:SINE:CREate:NAMed <Named>
Generates a signal and saves it to a waveform file.
Setting parameters:
<file name><Named>
BB:ARB:TSIG:SINE:CRE:NAM 'sine_test'
generates a test sine signal and saves it into the wavefile
sine_test.
Example:
Setting onlyUsage:
[:SOURce<hw>]:BB:ARB:TSIGnal:CIQ:I <I>
[:SOURce<hw>]:BB:ARB:TSIGnal:CIQ:Q <Tsig>
Sets the value for the Q component of the test signal
Parameters:
float
-0.5 to 0.5
0.001
0
FS
<Tsig>
Range:
Increment:
*RST:
Default unit:
BB:ARB:TSIG:CIQ:Q 0.5
sets the value for the Q component of the test signal.
Example:
[:SOURce<hw>]:BB:ARB:TSIGnal:RECTangle:AMPLitude <Amplitude>
Sets the digital amplitude of the rectangular wave.
Parameters:
float
0.0 to 1.0
0.1
FS
<Amplitude>
Range:
Increment:
Default unit:
BB:ARB:TSIG:RECT:AMPL 0.5
sets the amplitude of the test signal
Example:
[:SOURce<hw>]:BB:ARB:TSIGnal:RECTangle:FREQuency <Frequency>
The command sets the frequency of the test signal.
SOURce Subsystem