Remote Control Commands
R&S
®
SMU200A
738Operating Manual 1007.9845.32 ─ 15
SOUR:BBIN:SRAT:FIFO:STATus?
queries the FIFO Status of the sample rate.
Example:
Query onlyUsage:
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe:SOURce <Source>
This command selects the source for setting the sample rate of the digital I/Q output
signal.
Note: With a connected R&S EX-IQ-Box either the internal clock source (User defined)
or an external clock (Digital I/Q In) can be selected in the settings dialog of the R&S EX-
IQ-Box. Therefore, the sample rate source is only indicated in this field.
Parameters:
USER|DIN|DOUT | USER|DOUT | DIN
USER
The internally generated clock reference signal is used (option
R&S SMU-B13). The sample rate is calculated and displayed in
the field "Value".
DIN
An external clock reference signal is used. The clock signal is fed
in via a "Baseband Input Module" (option R&S SMU-B17). The
sample rate is estimated and displayed in the field "Value".
DOUT
An external clock reference signal is used. The clock signal is
directly fed in via pin CLK2 of the digital output interface (option
R&S SMU-B18, Digital I/Q Out). The sample rate is displayed in
the field "Value".
USER
<Source>
*RST:
IQ:OUTP:DIG:SRAT:SOUR USER
the internally generated clock reference signal is selected.
Example:
[:SOURce<hw>]:IQ:OUTPut:DIGital:STATe <State>
This command switches on and off the digital I/Q output signals.
Parameters:
0|1|OFF|ON
OFF
<State>
*RST:
IQ:OUTP:DIG:STAT ON
the digital I/Q output signals of path A are activated.
Example:
B13 and B18Options:
SOURce Subsystem