Description: Sets the fixed, upper torque limit.
Dependency: Refer to: p1521, p1522, p1523, r1538, r1539
Danger: Negative values when setting the upper torque limit (p1520 < 0) can result in the motor accelerating in an uncontrol-
lable fashion.
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note: The torque limit is limited to 400% of the rated motor torque. When automatically calculating the motor/closed-loop
control parameters (p0340), the torque limit is set to match the current limit (p0640).
Description: Sets the fixed, lower torque limit.
Dependency: Refer to: p1520, p1522, p1523
Danger: Positive values when setting the lower torque limit (p1521 > 0) can result in the motor accelerating in an uncontrol-
lable fashion.
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note: The torque limit is limited to 400% of the rated motor torque. When automatically calculating the motor/closed-loop
control parameters (p0340), the torque limit is set to match the current limit (p0640).
Description: Sets the signal source for the upper torque limit.
Dependency: Refer to: p1520, p1521, p1523
Danger: Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
p1520[0...n] CO: Torque limit upper / M_max upper
Access level: 2 Calculated: p0340 = 1,3,5 Data type: FloatingPoint32
Can be changed: U, T Scaling: p2003 Data set: DDS, p0180
Units group: 7_1 Unit selection: p0505
Min Max Factory setting
-1000000.00 [Nm] 20000000.00 [Nm] 0.00 [Nm]
p1521[0...n] CO: Torque limit lower / M_max lower
Access level: 2 Calculated: p0340 = 1,3,5 Data type: FloatingPoint32
Can be changed: U, T Scaling: p2003 Data set: DDS, p0180
Units group: 7_1 Unit selection: p0505
Min Max Factory setting
-20000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p1522[0...n] CI: Torque limit upper / M_max upper
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: p2003 Data set: CDS, p0170
Units group: - Unit selection: -
Min Max Factory setting
- - 1520[0]