Function diagrams
Free Function Blocks
2-618
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Fig. 2-113 7232 – PDE (switch-in delay)
- 7232 -
Function diagram
87654321
FP_7232_97_51.vsd
Time function blocks
G120 CU240B/E-2
13.12.2010 V4.4
PDE (switch-in delay)
PDE 1
PDE 0
IQ
T
PDE 0 RTG
5 ... 9999
p20161 (9999)
PDE 0 t_del ms
0.00 ... 60000.00
p20159 (0.00)
PDE 0 RunSeq
0 ... 32000
p20162 (430)
(0)
PDE 0 inp_pulse I
p20158
PDE 0 output Q
r20160
T0
IQ
T
PDE 1 RTG
5 ... 9999
p20166 (9999)
PDE 1 t_del ms
0.00 ... 60000.00
p20164 (0.00)
PDE 1 RunSeq
0 ... 32000
p20167 (440)
(0)
PDE 1 inp_pulse I
p20163
PDE 1 output Q
r20165
T0
PDE 3
PDE 2
IQ
T
PDE 2 RTG
5 ... 9999
p20337 (9999)
PDE 2 t_del ms
0.00 ... 60000.00
p20335 (0.00)
PDE 2 RunSeq
0 ... 32000
p20338 (890)
(0)
PDE 2 inp_pulse I
p20334
PDE 2 output Q
r20336
T0
IQ
T
PDE 3 RTG
5 ... 9999
p20342 (9999)
PDE 3 t_del ms
0.00 ... 60000.00
p20340 (0.00)
PDE 3 RunSeq
0 ... 32000
p20343 (900)
(0)
PDE 3 inp_pulse I
p20339
PDE 3 output Q
r20341
T0