Parameters
List of Parameters
1-94
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Sets the signal source for terminal DO 0 (NO: T. 19 / NC: T. 18).
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: DO: Digital Output
T: Terminal
Relay output: NO = normally open, NC = normally closed
Description: Sets the signal source for terminal DO 1 (NO: T. 21).
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: DO: Digital Output
T: Terminal
Relay output: NO = normally open, NC = normally closed
Description: Sets the signal source for terminal DO 2 (NO: T. 24 / NC: T. 23).
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: DO: Digital Output
T: Terminal
Relay output: NO = normally open, NC = normally closed
Description: Displays the status of digital outputs.
Note: DO: Digital Output
T: Terminal
Relay output: NO = normally open, NC = normally closed
Inversion using p0748 has been taken into account.
p0730 BI: CU signal source for terminal DO 0 / CU S_src DO 0
Access level: 2 Calculated: - Data type: U32 / Binary
Can be changed: U, T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 52.3
p0731 BI: CU signal source for terminal DO 1 / CU S_src DO 1
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 2 Calculated: - Data type: U32 / Binary
Can be changed: U, T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 52.7
p0732 BI: CU signal source for terminal DO 2 / CU S_src DO 2
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 2 Calculated: - Data type: U32 / Binary
Can be changed: U, T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 52.2
r0747 CU, digital outputs status / CU DO status
CU240B-2
CU240B-2 DP
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DO 0 (NO: T. 19 / NC: T. 18) High Low -