Description: Displays result list 1 that, for the crosswise data comparison between the monitoring channels, led to the fault.
Index: [0] = Result list processor 2
[1] = Result list processor 1
Dependency: Refer to: C01711
Note: SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
SLS: Safely-Limited Speed
Description: Displays the current motor-side position actual value for the motion monitoring functions on processor 1.
r9710[0...1] SI Motion diagnostics result list 1 / SI Mtn res_list 1
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
06 Actual value > upper limit, SLS1 Yes No -
07 Actual value > lower limit, SLS1 Yes No -
08 Actual value > upper limit, SLS2 Yes No -
09 Actual value > lower limit, SLS2 Yes No -
10 Actual value > upper limit, SLS3 Yes No -
11 Actual value > lower limit, SLS3 Yes No -
12 Actual value > upper limit, SLS4 Yes No -
13 Actual value > lower limit, SLS4 Yes No -
16 Actual value > upper limit, SAM/SBR Yes No -
17 Actual value > lower limit, SAM/SBR Yes No -
18 Actual value > upper limit SDI positive Yes No -
19 Actual value > lower limit SDI positive Yes No -
20 Actual value > upper limit SDI negative Yes No -
21 Actual value > lower limit SDI negative Yes No -
r9712 SI Motion diagnostics pos. act. val. motor side (processor 1) / SI Mtn s_act motP1
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -