Siemens SINAMICS G120 - p9383 SI Motion brake ramp monitoring time (processor 2); SI Mtn rp t_mon P2; p9386 SI Motion delay time of the evaluation sensorless (processor 2); SI Mtn t_del SL MM; p9387 SI Motion encoderless act val sensing filter time (processor 2); SI Mtn SL filt P2; p9388 SI Motion actual value sensing minimum current (processor 2); SI Mtn SL I_min P2

Siemens SINAMICS G120
750 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of Parameters
1-342
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Sets the monitoring time to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency: Refer to: p9381, p9382
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Description: Sets the evaluation delay for encoderless actual value sensing after pulse enable.
The value should be greater than or equal to the motor magnetizing time.
Dependency: Refer to: C01711
Description: Sets the filter time for smoothing the actual value with sensorless actual value sensing.
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Description: Sets the minimum current for encoderless actual value sensing in reference to 10 mA (i.e. when 1 % = 10 mA).
- The value must be increased if C30711 has occurred with message value 1042.
- The value must be decreased if C30711 has occurred with message value 1041.
Dependency: Refer to: C30711
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Reducing this percentage value can adversely affect actual value sensing.
p9383 SI Motion brake ramp monitoring time (processor 2) / SI Mtn rp t_mon P2
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
500.00 [ms] 1000000.00 [ms] 10000.00 [ms]
p9386 SI Motion delay time of the evaluation sensorless (processor 2) / SI Mtn t_del SL MM
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
5.00 [ms] 1000.00 [ms] 100.00 [ms]
p9387 SI Motion encoderless act val sensing filter time (processor 2) / SI Mtn SL filt P2
CU240E-2 DP F
CU240E-2 F
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0.00 [µs] 100000.00 [µs] 25000.00 [µs]
p9388 SI Motion actual value sensing minimum current (processor 2) / SI Mtn SL I_min P2
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0.00 [%] 1000.00 [%] 10.00 [%]