Siemens SINAMICS G120 - p9370 SI Motion acceptance test mode (processor 2); SI Mtn acc_mod P2; r9371 SI Motion acceptance test status (processor 2); SI Mtn acc_stat P2; p9381 SI Motion brake ramp reference value (processor 2); SI Mtn ramp ref P2; p9382 SI Motion brake ramp delay time (processor 2); SI Mtn rp t_del P2

Siemens SINAMICS G120
750 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Parameters
Parameters
1-341
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Setting to select and de-select the acceptance test mode.
Value: 0: [00 hex] De-select the acceptance test mode
172: [AC hex] Select the acceptance test mode
Dependency: Refer to: p9358, r9371
Refer to: C01799
Note: Acceptance test mode can only be selected if the motion monitoring functions, which are integrated in the drives,
are enabled (p9601.2/p9801.2).
Description: Displays the status of the acceptance test mode.
Value: 0: [00 hex] Acc_mode inactive
12: [0C hex] Acc_mode not possible due to POWER ON fault
13: [0D hex] Acc_mode not possible due to incorrect ID in p9370
15: [0F hex] Acc_mode not possible due to expired Acc_timer
172: [AC hex] Acc_mode active
Dependency: Refer to: p9358, p9370
Refer to: C01799
Description: Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency: Refer to: p9382, p9383
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Description: Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency: Refer to: p9381, p9383
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
p9370 SI Motion acceptance test mode (processor 2) / SI Mtn acc_mod P2
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: U, T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0000 hex 00AC hex 0000 hex
r9371 SI Motion acceptance test status (processor 2) / SI Mtn acc_stat P2
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0000 hex 00AC hex -
p9381 SI Motion brake ramp reference value (processor 2) / SI Mtn ramp ref P2
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
600.0000 [rpm] 24000.0000 [rpm] 1500.0000 [rpm]
p9382 SI Motion brake ramp delay time (processor 2) / SI Mtn rp t_del P2
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
10000.00 [µs] 99000000.00 [µs] 250000.00 [µs]