List of Parameters
Parameters
1-445
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Setting parameter for hysteresis HY of instance LVM 1 of the double-sided limiter.
Description: Display parameter of instance LVM 1 of the double-sided limiter that input quantity X was at least once X > M + L
and X is >= M + L - HY.
Description: Display parameter of instance LVM 1 of the double-sided limiter that the input quantity X lies within the interval.
Description: Display parameter of instance LVM 1 of the double-sided limiter that input quantity X was at least once X < M - L
and X is <= M - L + HY.
Description: Setting parameter for the run-time group in which instance LVM 1 of the double-sided limiter is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
p20278 LVM 1 hyst HY / LVM 1 hyst HY
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
r20279 BO: LVM 1 input quantity above interval QU / LVM 1 X above QU
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
r20280 BO: LVM 1 input quantity within interval QM / LVM 1 X within QM
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
r20281 BO: LVM 1 input quantity below interval QL / LVM 1 X below QL
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
p20282 LVM 1 run-time group / LVM 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
5 9999 9999