Parameters
List of Parameters
1-438
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Display parameter of instance LIM 1 of limiter QL (lower limit reached), i.e. QL = 1 for X <= LL.
Description: Setting parameter for the run-time group in which instance LIM 1 of the limiter is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance LIM 1 within the run-time group set in p20242.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X and of setting value SV of instance PT1 0 of the smoothing element.
Index: [0] = Input X
[1] = Setting value SV
Description: Sets the signal source for the "accept setting value" signal of instant PT1 0 of the smoothing element.
r20241 BO: LIM 1 input quantity at the lower limit QL / LIM 1 QL
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
p20242 LIM 1 run-time group / LIM 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
5 9999 9999
p20243 LIM 1 run sequence / LIM 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0 32000 650
p20244[0...1] CI: PT1 0 inputs / PT1 0 inputs
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 0
p20245 BI: PT1 0 accept setting value S / PT1 0 acc set val
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 0