List of Parameters
Parameters
1-93
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Displays the inverted status of the digital inputs.
Dependency: Refer to: r0722
Notice: To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note: DI: Digital Input
T: Terminal
Description: Displays the inverted status of the digital inputs.
Dependency: Refer to: r0722
Notice: To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note: DI: Digital Input
T: Terminal
Description: Sets the debounce time for digital inputs.
Note: The digital inputs are read in cyclically every 2 ms (DI 11, DI 12 every 4 ms).
To debounce the signals, the set debounce time is converted into integer multiple debounce clock cycles Tp (Tp =
p0724 / 2 ms).
DI: Digital Input
r0723.0...11 CO/BO: CU digital inputs, status inverted / CU DI status inv
CU240B-2
CU240B-2 DP
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (T. 5) High Low -
01 DI 1 (T. 6) High Low -
02 DI 2 (T. 7) High Low -
03 DI 3 (T. 8) High Low -
11 DI 11 (T. 3, 4) AI 0 High Low -
r0723.0...12 CO/BO: CU digital inputs, status inverted / CU DI status inv
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (T. 5) High Low -
01 DI 1 (T. 6) High Low -
02 DI 2 (T. 7) High Low -
03 DI 3 (T. 8) High Low -
04 DI 4 (T. 16) High Low -
05 DI 5 (T. 17) High Low -
11 DI 11 (T. 3, 4) AI 0 High Low -
12 DI 12 (T. 10, 11) AI 1 High Low -
p0724 CU digital inputs debounce time / CU DI t_debounce
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0.000 [ms] 20.000 [ms] 4.000 [ms]