Siemens SINAMICS G120 - r9794[0...19] SI crosswise comparison list (processor 1); SI CDC_list P1; r9795 SI diagnostics STOP F (processor 1); SI diag STOP F P1; r9798 SI actual checksum SI parameters (processor 1); SI act chksm P1; p9799 SI setpoint checksum SI parameters (processor 1); SI setp_chksm P1

Siemens SINAMICS G120
750 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of Parameters
1-374
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Displays the numbers of the data items that are currently being compared crosswise on processor 1.
The content of the list of crosswise-compared data is dependent upon the particular application.
Note: Example:
r9794[0] = 1 (monitoring clock cycle)
r9794[1] = 2 (enable safety functions)
r9794[2] = 3 (F-DI changeover, tolerance time)
...
A complete list of numbers for crosswise-compared data items appears in fault F01611.
Description: Displays the number of the cross-checked data item which caused STOP F on processor 1.
Dependency: Refer to: F01611
Note: A complete list of numbers for crosswise-compared data items appears in fault F01611.
Description: Displays the checksum for the Safety Integrated parameters checked using checksums on processor 1 (actual
checksum).
Dependency: Refer to: p9799, r9898
Description: Sets the checksum for the Safety Integrated parameters checked using checksums on processor 1 (setpoint check-
sum).
Dependency: Refer to: r9798, p9899
r9794[0...19] SI crosswise comparison list (processor 1) / SI CDC_list P1
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
r9795 SI diagnostics STOP F (processor 1) / SI diag STOP F P1
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 2 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
r9798 SI actual checksum SI parameters (processor 1) / SI act chksm P1
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
p9799 SI setpoint checksum SI parameters (processor 1) / SI setp_chksm P1
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex